collectd: Send metrics to collectd
The collectd() destination uses the unixsock plugin of the collectd application
to send log messages to the collectd system statistics collection daemon
. You must install and configure collectd separately before using this destination.
Prerequisites
-
AxoSyslog version 3.20 or later.
-
Install the
axosyslog-sclpackage on Debian/Ubuntu . On RHEL and compatible distributions , the SCL files are part of theaxosyslogbase package.Your configuration must also contain
@include "scl.conf", which the default configuration file already does. If the SCL files are missing, AxoSyslog fails to start with anunexpected LL_IDENTIFIERerror .Terminal window @include "scl.conf"The
collectd()driver is a reusable configuration snippet (SCL). For details on using or writing such configuration snippets, see Reusing configuration blocks. You can find its source in scl/collectd/plugin.conf on GitHub.
Declaration:
destination d_collectd {
collectd(
socket("<path-to-collectd-socket>"),
host("${HOST}"),
plugin("${PROGRAM}"),
type("<type-of-the-collected-metric>"),
values("<metric-sent-to-collectd>"),
);
};Example: Using the collectd() driver
The following example uses the name of the application sending the log message as the plugin name, and the value of the ${SEQNUM} macro as the value of the metric sent to collectd.
destination d_collectd {
collectd(
socket("/var/run/collectd-unixsock"),
host("${HOST}"),
plugin("${PROGRAM}"),
type("gauge"),
type_instance("seqnum"),
values("${SEQNUM}"),
);
};